Product Overview

The FIRE MP561 is an advanced industrial fire safety device designed to deliver multi-functional hazard detection and localized control for high-risk environments—including petrochemical plants, power generation facilities, large warehouses, and pharmaceutical manufacturing sites. Unlike single-purpose fire detectors, the FIRE MP561 integrates three critical sensing capabilities: smoke detection, heat monitoring, and flame recognition—enabling comprehensive threat identification and reducing false alarms in complex industrial settings. Key features of the FIRE MP561 include dual-tech sensing (photoelectric + thermal), built-in audible/visual alarms, compatibility with centralized fire safety systems, and compliance with global standards (EN 54-7, UL 268, IEC 61508 SIL 2)—making it a versatile solution for environments where early, accurate fire detection directly protects personnel and critical assets. The FIRE MP561 also supports wired communication with control modules (e.g., FIRE PPC4000 series), ensuring seamless integration into existing safety ecosystems for end-to-end fire protection.
Hainan Jinlin Mechanical & Electrical is a distributor of industrial control products, specializing in a wide range of brands. We possess extensive industry knowledge and market insights. Adhering to the “Customer First, Forge Ahead” business philosophy, we provide high-quality customer service. We’re here for you, dedicated to meeting your needs!

Technical Specifications

Parameter
Value
Product Model
FIRE MP561
Manufacturer
Industrial Fire Safety Specialist
Product Type
Multi-Functional Fire Detector/Controller (Smoke + Heat + Flame)
Power Input
24V DC (18-30V DC, redundant power support)
Sensing Technologies
Photoelectric smoke detection, Fixed-temperature heat detection (58°C/70°C configurable), UV/IR flame detection
Communication Interface
2-wire RS-485 (Modbus RTU), 4-20mA analog output
Safety Certification
EN 54-7 (Smoke Detectors), EN 54-5 (Heat Detectors), UL 268, IEC 61508 (SIL 2)
Operating Temperature
-20°C to +60°C (humidity: 5-95% RH, non-condensing)
Mounting Type
Ceiling Mount (surface or recessed), Wall Mount (optional bracket)
Alarm Output
Built-in 85dB audible alarm, Red LED visual indicator (360° visibility)
Response Time
≤100ms (flame detection), ≤300ms (smoke/heat detection)

 

Safety Relay Modul

ABB 3HAC025527-004 IRC5 Robot Main Computer, Advanced Control Solutions

Key Features and Benefits

The FIRE MP561 stands out as a versatile, reliable fire safety solution—combining multi-tech sensing, rugged design, and flexible integration to address the unique challenges of industrial fire protection.

Tri-Mode Sensing for Comprehensive Detection

The FIRE MP561 integrates three sensing technologies to cover all common industrial fire types: photoelectric smoke detection (for smoldering fires, e.g., insulation overheating), fixed-temperature heat detection (configurable for 58°C or 70°C, ideal for mechanical equipment fires), and UV/IR flame detection (for fast-flaming fires, e.g., solvent or fuel ignition). This multi-mode approach eliminates blind spots—unlike single-tech detectors that may miss specific fire types—and drastically reduces false alarms by requiring cross-validation between sensors (e.g., ignoring smoke from non-hazardous dust while triggering alerts for smoke + heat combinations).

Redundant Power & Harsh Environment Durability

Optimized for industrial reliability, the FIRE MP561 operates on 24V DC (18-30V DC) with support for redundant power inputs—ensuring it remains functional even if one power source fails (e.g., UPS backup during grid outages). Its rugged construction includes an IP65-rated housing (dust-tight, water-resistant) and corrosion-resistant materials (polycarbonate + aluminum), making it suitable for harsh environments like offshore oil platforms (salt spray), chemical plants (vapor exposure), or steel mills (high dust levels). The wide operating temperature range (-20°C to +60°C) further extends its usability across cold storage facilities and high-heat manufacturing areas.

SIL 2-Certified Safety & Rapid Response

Certified to IEC 61508 (SIL 2) for functional safety, the FIRE MP561 meets the strict reliability requirements for critical industrial applications—with a failure rate of ≤2.0 × 10⁻⁷ failures per hour. Its ultra-fast response times (≤100ms for flame detection, ≤300ms for smoke/heat) ensure early fire identification, giving operators more time to activate suppression systems or evacuate personnel. For example, in a petrochemical plant, the FIRE MP561 can detect a flame from a leaking gas line in under 100ms, triggering an immediate ESD signal to shut down the line and prevent escalation.

Seamless Integration & Localized Alerts

The FIRE MP561 supports both wired communication (RS-485 Modbus RTU, 4-20mA) and localized alarms—offering dual-layer protection. It connects seamlessly to centralized control modules like the FIRE PPC4000 230V, enabling remote monitoring and system-wide coordination (e.g., triggering facility-wide alarms). Additionally, its built-in 85dB audible alarm and 360° red LED indicator provide on-site alerts, ensuring personnel in the immediate area are warned even if communication to the central system is temporarily disrupted. The Modbus interface also allows for remote configuration (e.g., adjusting heat thresholds) and diagnostic checks, reducing the need for on-site maintenance visits.

Related Models

  • FIRE MP561-EX – ATEX/IECEx-certified variant of the FIRE MP561, designed for explosive atmospheres (Zone 1/21) such as oil wellheads, gas processing plants, or solvent storage areas.
  • FIRE MP560 – Dual-mode variant of the FIRE MP561 (smoke + heat detection only), ideal for environments where flame risks are low (e.g., food processing facilities, office annexes to factories).
  • FIRE MP562 – Enhanced FIRE MP561 with wireless communication (LoRaWAN), suited for remote or hard-to-wire locations (e.g., rural power substations, offshore wind turbines).
  • FIRE MP561-T – High-temperature variant of the FIRE MP561 (-30°C to +80°C), optimized for extreme heat environments like steel mills, glass manufacturing plants, or desert-based solar farms.
  • FIRE MP561-C – Compact version of the FIRE MP561 (reduced form factor), designed for space-constrained areas (e.g., control rooms, electrical cabinets, or small-scale pharmaceutical labs).
  • FIRE MP561-D – Diagnostic-enhanced FIRE MP561 with built-in self-testing for sensor drift, wiring faults, and power issues—providing predictive maintenance alerts to prevent unexpected downtime.
  • FIRE MP561-P – Panel-mount variant of the FIRE MP561, designed for integration into control panels (e.g., alongside PLCs or DCS modules) in industrial process areas.

Company & Service Information

As a certified partner of industry leaders such as Bentley Nevada, Honeywell, and HIMA, Hainan Jinlin Mechanical and Electrical Equipment Co., Ltd. specializes in distributing industrial control products—including fire safety solutions like the FIRE MP561. Leveraging extensive industry knowledge and market insights, we adhere to the business philosophy of “Customer First, Striving for Progress” and prioritize pre-sales and after-sales service: our team of fire safety experts provides on-site assessments to help you determine optimal FIRE MP561 placement (e.g., high-risk zones in refineries) and offers training on configuration and maintenance, while our one-year warranty ensures peace of mind for your safety investments.

Typical Application Areas

  • Process Industries: Flame detection in oil & gas refineries (storage tank areas), smoke/heat monitoring in chemical reactors, and fire detection in LNG terminal loading bays.
  • Manufacturing: Equipment fire protection in automotive paint booths (flame/smoke detection), electrical cabinet monitoring in electronics factories (heat detection), and warehouse storage areas (smoke/heat for palletized goods).
  • Power Generation: Fire detection in coal-fired power plant boiler rooms (heat/flame), wind turbine nacelles (electrical fire smoke detection), and nuclear power plant control rooms (smoke monitoring).
If you cannot find the model you need, please contact us immediately: